R-P16x16

R-P16x16

SOLENOIDS AND SOLUTIONS

QUALITY SINCE 1912

10

DC Cylindrical Solenoid
Rectifier for AC supply
Stroke up to 25mm
Pull and Push versions

Product group

Type R16 x 16
& RP 16 x 16

 Designed and manufactured in accordance with ISO 9001
 Long stroke design
 Pull version with integral clevis end
 Push version with threaded pushrod
 Increasing force characteristic (fig. 2)
Fig.1
R16 x 16 & RP16 x 16

 Threaded mounting nose with anti-rotation feature,
locknut and shakeproof washer

 Coil with unsulation to class B, for voltages up to 250 volts
 Protection classification – DIN VDE0470 / EN60529
IP00
Force, F

M

flying leads –

 UL rated materials of construction
 Zinc / nickel plated iron parts
 Suitable for operation in any attitude

Increasing

 Modifications and special designs on request
 Increased protection solenoid for arduous service on:
Machine tools

Office Machines

Motor vehicles

Remote control

Automation

Medical equipment

Packaging and coin equipment

Textile machinery

Magnet Schultz Limited
‘+44(0)1483 794700

3-4 Capital Park

7+44(0)1483 757298


Old Woking

close

open

Fig. 2
Force characteristic

Surrey

sales@magnetschultz.co.uk


GU22 9LD

Stroke, s

UK

www.magnetschultz.co.uk

Sales@magnetschultz.co.uk
‘+44(0)1483 794700

SOLENOIDS AND SOLUTIONS

QUALITY SINCE 1912

Performance and dimensional data for type R16 x 16 and RP16 x 16
R16 x 16 – Pull
Continuous
(CD) 100%

Duty Rating

Pulse
(PD) 10%

(mm)

0mm is completion of engerised stroke

Power Consumption P25

Continuous
(CD) 100%

Pulse
(PD) 10%

Magnetic force FM (N)

0

25.3

35.6

42.3

25.2

39.0

46.4

2

6.9

19.2

28.6

5.6

14.2

30.3

4

3.8

13.7

23.1

2.7

7.3

21.8

8

1.8

8.3

17.0

0.8

2.8

13.3

12

1.1

5.6

12.9

0.2

1.8

8.3

16

0.76

4.0

10.0

20

0.45

2.6

7.4

25

0.11

1.2

3.5

(Watts)

5.5

38

96

5.5

38

96

Armature Weight mA

(g)

Solenoid Weight mM

(g)

43

38
161

TABLE BASIS

24V / Continuous – Intermittent – Pulse duty
Mounted on steel plate 152 x 152 x 3mm
Horizontal working
Tolerance +/- 10% (inherent and manufacture)

POWER CONSUMPTION (P25)

Ambient temperature 250C
Free air mounted
Pull arrangement

Listed with 250C coil temperature (decrease/HOT)

MAGNETIC FORCE (FM)

RESIDUAL MAGNETISM

Listed in HOT condition at RATED voltage
Adjust for armature weight

With low force applications, plungers may hold in under residual magnetism
when the coil is deenergised. To prevent this, anti-residual springs are available,
but the force/stroke characteristic will be modified as a result

SUPPLY VOLTAGE

Standard DC: 24V – other voltages on request
Rectifier can be provided for AC Supply

DUTY RATING
The proportion of time that the solenoid is energised per operation cycle, shown in %

Order Example

Proportion (%) =

Type
Voltage
Duty rating

t (on)
______
x100

t (on) + t (off)

For each coil type: maximum energised (proportion) time/cycle Continuous: (100%) Intermittent: (10%) 60 secs Pulse: (5%) 0.1secs

4.7 x 12 DEEP

20.0 C0.76

R16 X 16
24v DC
Continuous

50.8 C0.8

150

Q11.1

18.0

4.0

Q3.2

M3x0.5 Fig 3
R16 x 16 and RP16 x 16

Intermittent
(ID) 25%

3/4-24 UNS – 2A
9.5

18 LONG

Q25.5 C0.25

5.0

Q5.7

Stroke s

Intermittent
(ID) 25%

RP16 x 16 – Push

32.1 C0.8

Data may be changed without prior notice – Dimensions not guaranteed

10.2 MAX.

Subject to our Standard Conditions

Q11.1

Dimensions in [mm] solenoid drawn
in energised condition

0907