5U7

5U7

SOLENOIDS AND SOLUTIONS
QUALITY SINCE 1912

D.C. Open Frame Solenoid

10

Rectifier for A.C supply
Stroke up to 12mm

Product group

Type 5U7


Increasing force characteristic

With integral clevis end for pull operation

Compact U – frame design for installation in
restricted space envelopes

Mounting by 4 x tapped holes in frame side

Zinc / nickel plated iron parts

Fig. 1


Coil with insulation to class B, for voltages up
to 250 volts

Protection classification – DIN VDE0470/EN60529
Tag connectors or flying leads – IP00

Force, F

M

Type 5U7


UL rated materials of construction

Suitable for operation in any attitude

Increasing


Spring return arrangement available
 Modifications and special designs on request

close

Magnet Schultz Limited
‘+44(0)1483 794700

Stroke, s

Office Machines
Remote control
Textile Machinery

3-4 Capital Park

7+44(0)1483 757298

open

Fig. 2
Force characteristic

 General purpose open frame solenoid for service on:
Machine tools
Automation
Packaging and coin equipment


Old Woking

Surrey

sales@magnetschultz.co.uk


GU22 9LD

UK

www.magnetschultz.co.uk

Sales@magnetschultz.co.uk
‘+44(0)1483 794700

SOLENOIDS AND SOLUTIONS

QUALITY SINCE 1912

Performance and dimensional data for type 5U7
5U7
Duty Rating

Continuous

Stroke s

(mm)

Power Consumption P25

Intermittent

Impulse

Magnetic force FM (N)

0

17.0

20.8

25.4

1

8.0

13.9

20.0

2

5.0

10.0

18.0

4

2.4

5.9

14.0

6

1.5

3.5

9.9

8

0.9

2.6

8.5

10

0.7

1.5

7.0

12

0.3

0.8

5.5

(Watts)

7

19

70

Armature Weight mA

(kg)

0.014

Solenoid Weight mM

(kg)

0.0895

TABLE BASIS

24V / impulse – intermittent – Continuous duty
Mounted on steel plate 152 x 152 x 3mm
Horizontal working
Tolerance +/- 10% (inherent and manufacture)

Ambient temperature 250C
Free air mounted
Pull arrangement

Conversion Factors

1N = 0.102 kp ≈ 0.1kp
1 Ncm = 0.102 kpcm ≈ 0.1 kcpm
1 kp = 1 kg = 2.2lbs
1 mm = 0.039 in
1 cmkp = 0.856 in. lbs

MAGNETIC FORCE (FM)

is�����������
listed in HOT
������������������������������
condition at RATED voltage
Adjust for armature weight

POWER CONSUMPTION (P25)

is listed with a 25 0c coil temperature (decrease/HOT)

DUTY RATING

SUPPLY VOLTAGE

4.75 x 0.51 Q.C.
(2x)

t (on)
_________
x 100

t (on) + t (off)
43.5 C0.8

Order Example

5U7
24v DC
Continuous

8.9

10.7
21.4

12.7

2.8

M3x0.5 (4x)
11.1

Type
Voltage
Duty Rating

23.0

12.7

3.4

Standard DC: 6V, 12V, 24V, 205V
Rectifier can be provided for AC Supply
Other voltages on request

10.8

The proportion of time that the solenoid is energised per operation cycle normally shown in %
Max. energised time/cycle: continuous (100%): intermittent (25%) – 60secs: impulse (10%) – 0.1secs

Available with quick connect
terminations (as shown) or with
150mm ± 10mm flying leads
(shown dashed)

Q7.90

Q3.2

11.9

19.1 C0.8

Data may be changed without prior notice – Dimensions not guaranteed

Subject to our Standard Conditions

0907